Dionex IonPac CS19 陽離子交換柱 076028這種大容量、羧酸功能柱是專門優化的常見陽離子的分離,極性小的有機胺,和適度的疏水性和多價使用簡單的水溶液洗脫液和高溫陽離子。
免費咨詢:010-61755520
分離極性胺與Thermo Scientific Dionex IonPac CS19陽離子交換柱。這種大容量、羧酸功能柱是專門優化的常見陽離子的分離,極性小的有機胺,和適度的疏水性和多價使用簡單的水溶液洗脫液和高溫陽離子。列是理想的發電廠水銨、嗎啉治療分析,或乙醇胺也可用于分析化學添加劑、化學工藝方案,除塵器的解決方案,個人護理產品和食品樣品。
Dionex IonPac CS19 陽離子交換柱 076028
訂貨信息:
Dionex IonPac CS19 陽離子交換柱
分析柱 | |
IonPac CS19 Capillary Column (0.4 x 250 mm) | 076024 |
IonPac CS19 Analytical Column (4 x 250 mm) | 076026 |
IonPac CS19 Analytical Column (2 x 250 mm) | 076028 |
保護柱 | |
IonPac CG19 Capillary Guard Column (0.4 x 50 mm) | 076025 |
IonPac CG19 Guard Column (4 x 50 mm) | 076027 |
IonPac CG19 Guard Column (2 x 50 mm) | 076029 |
The Thermo Scientific? Dionex? IonPac? CS19 carboxylate-functionalized cation-exchange column is tailored for the separation of six common cations, small polar amines (including alkanolamines and methylamines) and moderately hydrophobic and polyvalent amines (including biogenic amines and alkyl diamines) using simple aqueous eluents and elevated temperatures. The Dionex IonPac CS19 column is ideal for use with RFIC? systems for automatic methanesulfonic acid eluent generation.
For analysis of amines including alkanolamine and methylamines in diverse sample matrices
For analysis of moderately-hydrophobic amines including biogenic amines, alkyl diamines, and polyvalent amines
Optimized for simple acidic gradient separations with minimal baseline shift
Ideal Reagent-Free? electrolytic suppression with the Thermo Scientific Dionex CERS? 500 Cation Electrolytically Regenerating Suppressor?
Compatible with organic solvents, acetonitrile, and acetone up to 10%, excluding alcohols
High capacity allows routine analysis of high-ionic-strength samples
The Dionex IonPac CS19 cation-exchange column supports isocratic and gradient separations of polar amines, moderately hydrophobic amines, and polyvalent cations using suppressed conductivity detection. The Dionex IonPac CS19 column has a higher capacity than the Thermo Scientific Dionex IonPac CS18 column. This allows the analysis of widely disparate peak pairs and high-ionic strength matrices with less overloading of the column.
The Dionex IonPac CS19 column is targeted for analysis of power plant waters treated with ammonium, morpholine, or ethanolamine; as well as chemical additives; chemical process solutions; scrubber solutions; personal care products; and food samples.
The Dionex IonPac CS19 column is available in 4 × 250 mm, 2 × 250 mm, and 0.4 × 250 mm formats.The microbore and capillary formats require less eluent thereby reducing operating costs.
Thermo Scientific Dionex IonPac CS19 Cation-Exchange Column Specifications | |
---|---|
Dimensions: | Dionex IonPac CS19 Analytical Column: 4 × 250 mm Dionex IonPac CG19 Guard Column: 4 × 50 mm Dionex IonPac CS19 Analytical Column: 2 × 250 mm Dionex IonPac CG19 Guard Column: 2 × 50 mm Dionex IonPac CS19 Capillary Column: 0.4 × 250 mm Dionex IonPac CG19 Capillary Guard Column: 0.4 × 50 mm |
Maximum Operating Pressure: | 3000 psi (Standard, microbore and capillary) |
Mobile Phase Compatibility: | Acidic eluents, 0–10% HPLC solvents, excluding alcohols |
Substrate Characteristics: | Bead Diameter: 5.5 μm Crosslinking (%DVB): 55% |
Functional Group Characteristics: | Ion-Exchange Group: Grafted carboxylic acid Surface Characteristics: Medium hydrophobic |
Capacity: | 2410 μeq (4 × 250 mm analytical column) 46 μeq (4 × 50 mm guard column) 600 μeq (2 × 250 mm analytical column) 11 μeq (2 × 50 mm guard column) 24 μeq (0.4 × 250 mm capillary column) 0.5 μeq (0.4 × 50 mm capillary guard column) |
Column Construction: | PEEK? with 10-32 threaded ferrule style end fittings. All components are nonmetallic. (4 mm and 2 mm columns) |